500 lph ro plant

Description

500lph ro plant First of all we are talking about our valued customers that can avail the range of highly reliable Industrial RO Systems similarly 500lph ro plant that are developed as per international quality norms and client’s technical demands. Widely appreciated for optimum performance, high water carrying capacity and low maintenance, our range of Industrial RO Systems like 500 LPH are highly demanded across various industries such as hotels,schools,Delhi Metro, L & T,Hospitals,Nagar Nigams etc. Offered at industry leading rates our range has been successful in meeting clients’ demands and satisfy their water purification needs.
Features of 500lph ro plant:

  • Dimensionally accurate
  • Compact design
  • Flawless nature.

About 500lph ro plant
Pumps–CRI
Vessels_ pentair (FRP-1054)
pipe&fittings-Astral
ss skid
Description Features (500lph ro plant)
Technology : RO Membrane Based, (Model: 4040)
Electricity : 2.2KW/220v, 50Hz
Filtrations : Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration : Sand and Activated Carbon Filter, Micron Filter
Post Filtration : GAC
Design to Work : TDS up to 3000ppm, Hardness 1600mg/I
Operating Mode : Automatic + Manual
Monitoring Accessories : MMIC Panel, Pressure Gauges, Flow Meters etc.
1- Raw Water Pump used in 500lph ro plant):
Purpose: To feed the dual media filter at pressure more than 3.0 bars, which is min. operating pressure for filters.
Specifications:
Sl. Parameter Descriptions
(a) MOC CI
(b) Type Horizontal Centrifugal
(c) Flow Rate Min. 2200 Liters per hour
(d) Head 35m
(e) Power Required .75KW
(f) Electrical 220V, Single phase, 50HZ
(g) Cycle 2200 rpm
(h) Make CRI
(j) Quantity 1 One Nos.

2. Multi Grade Sand Filter:
Purpose: To remove the total suspended solids, dirt, iron, and reduce silt density Index, which can foul the membranes.
Sl. Parameter DESCRIPTIONS
(a) Make Pentair Water
(b) MOC FRP/Poly glass
(c) Diameter 10 x 54
(d) Quantity 1 One Set
(e) Media Anthracite, Pebble and Fine Sand

3. Activated Carbon Filter:
Purpose: To remove the excess acidic nature chemical, like; Chlorine etc, which can damage the membranes.
Sl. Parameter DESCRIPTIONS
(a) Make Pentair
(b) MOC FRP
(c) Diameter 10 x 54
(d) Quantity 1 One Set
(e) Media Activated Carbon 1000IDV

4. Piping:
Pipe of PVC 28 Bar tested pressure testing cock & pressure gauges at inlet-outlet of system
Sl. Parameter DESCRIPTIONS
(a) Make Astral
(b) MOC U-PVC
(c) Burst Pressure 28Kg/Bar
(d) Quantity 1 1 Lot

5. Micron Filter:
Purpose: To remove the fine particles up to 05 microns and reduce silt density Index levels to acceptable level.
Specifications:
Housing:
Sl. Parameter DESCRIPTIONS
(a) Make RAVE Filtration
(b) MOC of Housing PP
(c) Length 20”
(d) Diameter 5.5”
(e) Quantity One nos.
Cartridge
(f) Make Pure & Safe
(g) Cartridge MOC Polypropylene
(h) Length 20”
(i) Diameter 4”
(j) Quantity One nos.
(k) Micron Rating 05 Micron

6. High Pressure Pump:
Purpose: To Feed the Reverse Osmosis Membrane at pressure more than the osmotic pressure taking into consideration flux rate, flow and recovery.
Specifications:
Sl. Parameter DESCRIPTIONS
(a) MOC Stainless Steel
(b) Type Vertical Multistage
(c) Flow Rate 4000Liters Per Hours
(d) Head 160mwc
(e) Power Required 1.1 KW
(f) Electrical 220V, single phase, 50HZ
(g) Cycle 2900 RPM
(h) Make CRI
(i) Quantity 1 One nos.

7. RO Membrane Module:
Purpose: To remove the major part of TDS up to 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow and recovery.
Specifications:
Sl. Parameter DESCRIPTIONS
(a) Type Spiral Wounded
(b) Diameter of Membrane 4.0 Inch
(c) Length of Membrane 40” Inch
(d) No. of Membranes 2 Two nos.
(e) Recovery per Membrane 10-15%
(f) Salt rejection per Membrane Up to 99%
(g) Make of Membrane CSM/LG
(h) System Recovery Up to 40%
8. RO Pressure Vessel:
Purpose: To pack Reverse Osmosis Membranes and operate at high pressure up to300 psi.
Specifications:
Sl. Parameter DESCRIPTIONS
(a) MOC FRP
(b) Diameter of pressure Vessel 4.5 Inch
(c) Length of Pressure vessel 2.2m
(d) No. of Pressure vessel 2
(e) No. of Membrane per vessel 1
(f) Make Pentair
(g) Position Horizontal, Series
(h) Arrays 1 No.

9. >Electrical Panel< Purpose: Control Panel is provided as a safety measure for the pump & other electrical items. Specifications: Sl. DESCRIPTIONS (a) Complete Starters, overload relays. (b) Voltmeter, Ammeter, MCB’s Indicating Lights (c) Push Buttons (d) Rocker switches for dozers (e) Incomers Auto-manual switches 10.Instrumentation Sl. Equipment’s Specifications (a) Flow Meter To measure the online flow of water (b) Pressure Switches To Protect RO system from different water pressure (c) Pressure Gauges For calculate ^ P for each unit in RO system