valued customers can avail the range of highly reliable Industrial RO Systems 4000lph ro plant that are developed as per international quality norms and client’s technical demands. Widely appreciated for optimum performance, high water carrying capacity and low maintenance, our range of Industrial RO Systems 5000lph ro plant are highly demanded across various industries. Offered at industry leading rates our range has been successful in meeting clients’ demands and satisfy their water purification needs.

>BASIC DESIGN SPECIFICATION (5000lph ro plant / Model- DLX)< Description / Model: 5000lph ro plant Permeate Flow rate : 5000 LPH Dimensions (In Inch.): 140(L) X 60(W) X 80(H) Power consumption : 5.5 KW / 440 Volt Design Specification : Automatic + Manual Feed water pressure: 3.5 Kg/cm2 TDS (Designed) Raw Water: <3000ppm Feed water hardness (Designed): <750ppm Make of RO High Pressure Pumps: Grundfos Pump (Denmark) Make of RO Membranes : Hydronautics (USA) II. Equipment list of 5000lph ro plant (DLX Model) Sl. Equipment Name Model - DLX-5000 Qty 1 Set RO Recovery @ 65% 1 Raw Water Pump (RWP)- 2 no, Grundfoss, 1.2KW/440V 2 Dual Media Filter (DMF)-- Pentair 3072 with PVC M/P Valve (Initiative) 3 Activated Carbon Filter (ACF) 1 set,FRP vessel, Pentair 3072 with PVC M/P Valve (Initiative) and Filter Media (Carbon 1000 IDV) (USA) 4 Micron Filter (MF) 4no, Imported, SS 304, Filter housing with PP cartridge 10 & 5 Micron 5 High Pressure Pump in 5000lph ro plant - 1 no Grundfos Vertical SS 316 construction HP Pump, Flow 7.9m3/hr, Head- 130M Model- 5-29/ 415V (Denmark) 6 RO Membrane (RM) 4 Set CPA2 8040 RO Membrane Hydronautics (USA) 7 RO Membrane Housing (MH) 2 no Pentair CodeLine-8080 FRP Housing PR-300psi (USA) 8 Electric Control Panel (ECP) 1 no DOL Control panel with auto operation, errors detection and Alarm by L&T 9 Flow Meter (RM) 2 no Rust free Acrylic body by Aster 10 Pressure Gauges (PG) 5 no H Guru (SS304) 11 Pipe & fittings 1 lot All pressure line in SS304 12 RO Skid 1 no SS304 skid & nut - bolts 13 Others 1 lot Float Sensors IV. Equipment wise Technical specifications of RO Plants: 1- Raw Water Pump: Purpose: To feed water pump maintain 3.5 Bar operating pressure to pre filtration process take place. Specifications: Sl. Parameter Qty. Descriptions (a) MOC SS304 (b) Type Horizontal Centrifugal (c) Flow Rate 8m3/Hr. (d) Head 35m (e) Power Required 1.2 KW (f) Electrical 220V, 50HZ (g) Cycle 2900 rpm (h) Make Grundfos (i) Model CM5-4 (j) Quantity 2 Set Working and standby 2. Multi Grade Filter: Purpose: To remove turbidity and suspended solids by filtration bed and control flux rate. Specifications: Sl. Parameter Qty. DESCRIPTIONS (a) Make Pentair Water (b) MOC Polyethylene FRP (c) Diameter 750mm x 1800mm (d) Quantity 1 Set 1 Set (e) Media Pebbles, Gravels and Sand (f ) Qty. Media Filling 550 Kg Five Hundred Fifty Kilogram 3. Activated Carbon Filter: Purpose: To remove the unwanted chemical i.e. Chlorine. Which caused damage membranes Specifications: Sl. Parameter Qty. DESCRIPTIONS (a) Make Pentair Water (b) MOC Polyethylene FRP (c) Diameter 750mm x 1800mm (d) Quantity 1 Set 1 Set (e) Media Activated Carbon 1000IDV (f ) Qty. Carbon Filling 500 Kg Five Hundred Kilogram 4. Piping and Fittings: Internal Piping of high pressure line in SS 304 and low pressure line in U-PVC for capacity 25 Bar tested pressure, testing cock & various fittings of system Specifications: Sl. Parameter Qty. DESCRIPTIONS (a) Make Astral / Jindal (b) MOC SS304 (c ) Burst Pressure 26 Bar (d) Quantity 1 Lot Battery Limit (e) Size 42 mm 5. Micron Filter: Purpose: To remove the fine particles up to 05 microns and reduce silt density Index levels to acceptable level. Specifications: Housing: Sl. Parameter Qty. DESCRIPTIONS (a) Make Azud (Spain) (b) MOC Modular Plastic (c) Length 625mm (d) Diameter 250mm (e) Quantity 1 Set One Set Cartridge (f) Make AZUD Helical System (g) Cartridge MOC Modular Disc (h) Length 500mm (i) Diameter 65mm (j) Quantity 1 Nos. one (k) Micron Rating 5 Micron 6. High Pressure Pump used in 4000lph ro plant :
Purpose: To Feed the Reverse Osmosis Membrane at pressure more than the osmotic pressure taking into consideration flux rate, flow and recovery.
Specifications:
Sl. Parameter DESCRIPTIONS
(a) MOC Stainless Steel 304
(b) Type Centrifugal Multistage Vertical Pump
(c) Flow Rate 7m3/hr
(d) Head 140mwc
(e) Model CR5-29
(f) Power Required 4 KW
(g) Electrical 440V, 50HZ
(h) Cycle 2900 RPM
(i) Make Grundfos (Denmark)
(j) Quantity 2 Set. Working and Standby Pumps with Motor

7. RO Membranes in 4000lph ro plant:
Purpose: To remove the major part of TDS up to 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow and highest recovery.
Specifications:
Sl. Parameter Qty. DESCRIPTIONS
(a) Type Spiral Wounded
(b) Model of Membrane and size 8040 (8”x40”)
(c) MOC of Membrane Thin Film Composite
(d) No. of Membranes 4 No. Four no.
(e) Recovery of Membranes Max 6%
(f) Salt rejection per Membrane Max 99.8%
(g) Make of Membrane Hydronautics ,USA

9. RO Pressure Vessel in 4000lph ro plant:
Purpose: To pack Reverse Osmosis Membranes and operate at high pressure up to300 psi.
Specifications:
Sl. Parameter Qty. DESCRIPTIONS
(a) MOC FRP (Fiber Reinforce Plastic)
(b) Dimension of pressure Vessel 200mm x 2000mm
(c) Pressure Rating 300 psi
(d) No. of Pressure vessel 2 Set Two set
(e) No. of Membrane per vessel 2 Nos.
(f) Make Pentair Water, USA.
(g) Position Horizontal in Series
(h) Model and type Code-Line Side port

10. Electrical Panel :
Made with 14 Gage CRC sheet. Multiple electric controllers and timers are provided for electric supply to the pumps & various electrical items within the RO plants.
Make : Delta Pure with L&T products
Sl. DESCRIPTIONS
(a) Complete Starters, overload relays and Main TPN MCB
(b) Voltmeter, Ammeter and LED Indicating Lights
(c) Push Buttons and Emergency Button
(d) Rocker switches for dozers
(e) Incomers Auto-manual switches
(f) Auto+ Manual operation in case of emergency

11. Instrumentation

Specifications:
(a) Rota Meter: Description
Quantity 2 No.(Permeate and Reject )
Range Up to 8.0 cum. per hour
Make Aster

(b)Pressure Gauges Description
Application 6 Monitoring on various pressure point
Range 0-21 Bar
Type Bourdon
Make H-Guru/ Mass
MOC SS 316

(c) Level Sensors Description
Application 2 Automation of RAW + RO tank
Range 15 AMP/AC 220V
Make Delta Pure