Our valued customers can avail the range of highly reliable Industrial RO Systems 1000lph ro plant that are developed as per international quality norms and client’s technical demands. Widely appreciated for optimum performance, high water carrying capacity and low maintenance, our range of Industrial RO Systems 1000 LPH are highly demanded across various industries. Offered at industry leading rates our range has been successful in meeting clients’ demands and satisfy their water purification needs.


Description Features of 1000LPH ro plant

Technology : RO Membrane Based, (Model: 4040)
Electricity : 3.2KW/220v, 50Hz
Filtrations : Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.

Pre Filtration : Sand and Activated Carbon Filter, Micron Filter
Design to Work
Design to Work : TDS up to 3000ppm, Hardness 1600mg/I
Operating Mode : Automatic + Manual

Monitoring Accessories : MMIC Panel, Pressure Gauges, Flow Meters etc.
1- RAW WATER PUMP uded in Industrial RO Plant 1000LPH:
Purpose: To feed the dual media filter at pressure more than 3.0 bars, which is min. operating pressure for filters.

>Specifications<
Sl. Parameter Descriptions
(a) MOC CI
(b) Type Horizontal Centrifugal
© Flow Rate Min. 2200 Liters per hour
(d) Head 35m
(e) Power Required .75KW
(f) Electrical 220V, Single phase, 50HZ
(g) Cycle 2900 rpm
(h) Make CRI
(j) Quantity 1 One Nos.

2. Multi Grade Sand and Activated Carbon Filter
Purpose: To remove the total suspended solids, dirt, iron, and reduce silt density Index which can foul the membranes and also absorb any type of colour,odour & test.
Sl. Parameter DESCRIPTIONS
(a) Make Pentair Water
(b) MOC FRP/Poly glass
© Diameter 14 x 65
(d) Quantity 1 Two Set
(e) Media Anthracite, Pebble, Fine Sand& Activated Carbon 1000IDV

3. PIPING:
Pipe of PVC 28 Bar tested pressure testing cock & pressure gauges at inlet-outlet of system
Sl. Parameter DESCRIPTIONS
(a) Make Astral
(b) MOC U-PVC
© Burst Pressure 28Kg/Bar
(d) Quantity 1 1 Lot
4. MICRON FILTER:
Purpose: To remove the fine particles up to 05 microns and reduce silt density Index levels to acceptable level.

Housing:
Sl. Parameter DESCRIPTIONS
(a) Make RAVE Filtration
(b) MOC of Housing PP
© Length 20”
(d) Diameter 5.5”
(e) Quantity Two nos.
Cartridge
(f) Make Pure & Safe
(g) Cartridge MOC Polypropylene
(h) Length 20”
(i) Diameter 4”
(j) Quantity Two nos.
(k) Micron Rating 05 Micron + 10 Micron

5. HIGH PRESSURE PUMP used in 1000LPH ro plant:
Purpose: To Feed the Reverse Osmosis Membrane at pressure more than the osmotic pressure taking into consideration flux rate, flow and recovery.
Specifications:
Sl. Parameter DESCRIPTIONS of ro plant 1000lph:
(a) MOC Stainless Steel
(b) Type Vertical Multistage
© Flow Rate 3000Liters Per Hours
(d) Head 150mwc
(e) Power Required 2.2 KW
(f) Electrical 220V, Single phases, 50HZ
(g) Cycle 2900 RPM
(h) Make CRI Pumps (2-18)
(i) Quantity 1 One nos.

6. RO MEMBRANE MODULE of ro plant 1000lph :
Purpose: To remove the major part of TDS up to 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow and recovery.
Specifications:
Sl. Parameter DESCRIPTIONS of 1000lph ro plant:
(a) Type Spiral Wounded
(b) Diameter of Membrane 4.0 Inch
© Length of Membrane 40” Inch
(d) No. of Membranes 4 Four nos.
(e) Recovery per Membrane 10-15%
(f) Salt rejection per Membrane Up to 99%
(g) Make of Membrane Vontron
(h) System Recovery Up to 40%

7. RO PRESSURE VESSEL:
Purpose: To pack Reverse Osmosis Membranes and operate at high pressure up to300 psi.
Specifications:
Sl. Parameter DESCRIPTIONS
(a) MOC FRP LINQ
(b) Diameter of pressure Vessel 4.5 Inch
© Length of Pressure vessel 2.2m
(d) No. of Pressure vessel 2
(e) No. of Membrane per vessel 2
(f) Make LINQ
(g) Position Horizontal, Parallel
(h) Arrays 1 No.

08. ELECTRICAL PANEL
Purpose: Control Panel is provided as a safety measure for the pump & other electrical items.
Specifications:
Sl. DESCRIPTIONS
(a) Complete Starters, overload relays.
(b) Voltmeter, Ammeter, MCB’s Indicating Lights
(c) Push Buttons
(d) Rocker switches for dozers
(e) Incomers Auto-manual switches

10.INSTRUMENTATION
Sl. Equipment’s Specifications
(a) Flow Meter To measure the online flow of water
(b) Pressure Gauges For calculate ^ P for each unit in RO system

Features:

  • Dimensionally accurate
  • Compact design
  • Flawless nature.

 
industrial ro plant 1000lph1000lph ro plant

500lph ro plant First of all we are talking about our valued customers that can avail the range of highly reliable Industrial RO Systems similarly 500lph ro plant that are developed as per international quality norms and client’s technical demands. Widely appreciated for optimum performance, high water carrying capacity and low maintenance, our range of Industrial RO Systems like 500 LPH are highly demanded across various industries such as hotels,schools,Delhi Metro, L & T,Hospitals,Nagar Nigams etc. Offered at industry leading rates our range has been successful in meeting clients’ demands and satisfy their water purification needs.
Features of 500lph ro plant:

  • Dimensionally accurate
  • Compact design
  • Flawless nature.

About 500lph ro plant
Pumps–CRI
Vessels_ pentair (FRP-1054)
pipe&fittings-Astral
ss skid
Description Features (500lph ro plant)
Technology : RO Membrane Based, (Model: 4040)
Electricity : 2.2KW/220v, 50Hz
Filtrations : Suspended Solids, Chemical Impurities, Bacteria like Cryptosporidium, Pseudomonas, and Pathogens e-coli.
Pre Filtration : Sand and Activated Carbon Filter, Micron Filter
Post Filtration : GAC
Design to Work : TDS up to 3000ppm, Hardness 1600mg/I
Operating Mode : Automatic + Manual
Monitoring Accessories : MMIC Panel, Pressure Gauges, Flow Meters etc.
1- Raw Water Pump used in 500lph ro plant):
Purpose: To feed the dual media filter at pressure more than 3.0 bars, which is min. operating pressure for filters.
Specifications:
Sl. Parameter Descriptions
(a) MOC CI
(b) Type Horizontal Centrifugal
(c) Flow Rate Min. 2200 Liters per hour
(d) Head 35m
(e) Power Required .75KW
(f) Electrical 220V, Single phase, 50HZ
(g) Cycle 2200 rpm
(h) Make CRI
(j) Quantity 1 One Nos.

2. Multi Grade Sand Filter:
Purpose: To remove the total suspended solids, dirt, iron, and reduce silt density Index, which can foul the membranes.
Sl. Parameter DESCRIPTIONS
(a) Make Pentair Water
(b) MOC FRP/Poly glass
(c) Diameter 10 x 54
(d) Quantity 1 One Set
(e) Media Anthracite, Pebble and Fine Sand

3. Activated Carbon Filter:
Purpose: To remove the excess acidic nature chemical, like; Chlorine etc, which can damage the membranes.
Sl. Parameter DESCRIPTIONS
(a) Make Pentair
(b) MOC FRP
(c) Diameter 10 x 54
(d) Quantity 1 One Set
(e) Media Activated Carbon 1000IDV

4. Piping:
Pipe of PVC 28 Bar tested pressure testing cock & pressure gauges at inlet-outlet of system
Sl. Parameter DESCRIPTIONS
(a) Make Astral
(b) MOC U-PVC
(c) Burst Pressure 28Kg/Bar
(d) Quantity 1 1 Lot

5. Micron Filter:
Purpose: To remove the fine particles up to 05 microns and reduce silt density Index levels to acceptable level.
Specifications:
Housing:
Sl. Parameter DESCRIPTIONS
(a) Make RAVE Filtration
(b) MOC of Housing PP
(c) Length 20”
(d) Diameter 5.5”
(e) Quantity One nos.
Cartridge
(f) Make Pure & Safe
(g) Cartridge MOC Polypropylene
(h) Length 20”
(i) Diameter 4”
(j) Quantity One nos.
(k) Micron Rating 05 Micron

6. High Pressure Pump:
Purpose: To Feed the Reverse Osmosis Membrane at pressure more than the osmotic pressure taking into consideration flux rate, flow and recovery.
Specifications:
Sl. Parameter DESCRIPTIONS
(a) MOC Stainless Steel
(b) Type Vertical Multistage
(c) Flow Rate 4000Liters Per Hours
(d) Head 160mwc
(e) Power Required 1.1 KW
(f) Electrical 220V, single phase, 50HZ
(g) Cycle 2900 RPM
(h) Make CRI
(i) Quantity 1 One nos.

7. RO Membrane Module:
Purpose: To remove the major part of TDS up to 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow and recovery.
Specifications:
Sl. Parameter DESCRIPTIONS
(a) Type Spiral Wounded
(b) Diameter of Membrane 4.0 Inch
(c) Length of Membrane 40” Inch
(d) No. of Membranes 2 Two nos.
(e) Recovery per Membrane 10-15%
(f) Salt rejection per Membrane Up to 99%
(g) Make of Membrane CSM/LG
(h) System Recovery Up to 40%
8. RO Pressure Vessel:
Purpose: To pack Reverse Osmosis Membranes and operate at high pressure up to300 psi.
Specifications:
Sl. Parameter DESCRIPTIONS
(a) MOC FRP
(b) Diameter of pressure Vessel 4.5 Inch
(c) Length of Pressure vessel 2.2m
(d) No. of Pressure vessel 2
(e) No. of Membrane per vessel 1
(f) Make Pentair
(g) Position Horizontal, Series
(h) Arrays 1 No.

9. >Electrical Panel< Purpose: Control Panel is provided as a safety measure for the pump & other electrical items. Specifications: Sl. DESCRIPTIONS (a) Complete Starters, overload relays. (b) Voltmeter, Ammeter, MCB’s Indicating Lights (c) Push Buttons (d) Rocker switches for dozers (e) Incomers Auto-manual switches 10.Instrumentation Sl. Equipment’s Specifications (a) Flow Meter To measure the online flow of water (b) Pressure Switches To Protect RO system from different water pressure (c) Pressure Gauges For calculate ^ P for each unit in RO system

iron removal plantWe provide all types of chemicals used in Industrial RO Plant such as anti scalant ,ph booster,membrane cleaner etc.Necsal commercials Pvt.Ltd. is a complete water solution company.It manufactures all type of domestic RO system as well as commercial and industrial RO machines and plants.It also installed STP,WTP,ETP and Rain water harvesting system as well as chemical removal plants such as iron removal plant ,arsenic removal plant ,fluoride removal plant

=PmUgahref=”https://necsalgroup.com/product/iron-removal-plant/https://www.youtube.com/watch?MXD6p0″>.It also deals in spare parts of all type of Domestic ro System and commercials as well as industrial plants.Our valued customers can avail the range of highly reliable Domestic RO Systems 10 LPH that are developed as per international quality norms and client’s technical demands. Widely appreciated for optimum performance, high water carrying capacity and low maintenance, our range of Industrial RO Systems 1000 LPH are highly demanded across various industries. Offered at industry leading rates our range has been successful in meeting clients’ demands and satisfy their water purification needs.

Our company M/s Necsal Commercial Pvt. Ltd. manufactures and sells Reverse Osmosis Systems ( Domestic RO system, Commercial & Industrial), Water Softener( Domestic, Commercial & Industrial) as well as Waste Water Treatment Plant.It also install RAIN WATER HARVESTING UNIT. We offer you a cleaner, safer and healthier lifestyle through our products such as Reverse Osmosis Systems followed by reliable after sales service of our Water Softener Plant. Our motto is to provide quality at most competitive rates.
Looking forward to a positive response and long term association with your esteemed organisation among our vast number of clients like. St. George School, Shri Venkateshwar School, Lenco, Subrosa,Eros Group,etc large number of offices, commercial institutes, hotels, restaurants, educational, charitable & domestic users etc.
Reference your discussion with us, we are giving you our most reasonable discounted rates for service.
< href="https://necsalgroup.com/product/iron-removal-plant/https://www.youtube.com/watch?v=PmUgaMXD6p0">

Descriptions of Iron Removal Plant:-
1. Multi Grade Sand Filter:
Purpose: To remove the total suspended solids, dirt, iron, and reduce silt density Index, which can foul the membranes.
Sl. Parameter DESCRIPTIONS
(a) Make Pentair Water
(b) MOC FRP/Poly glass
(c) Diameter 30″ height 72″
(d) Quantity 1 One Set
(e) Media Anthracite, Pebble and Fine Sand

2. Iron removal Filter used in Iron removal plant:
Purpose: To remove the excess iron
.
Sl. Parameter DESCRIPTIONS
(a) Make Pentair
(b) MOC FRP
(c) Diameter 36 height 72″
(d) Quantity 1 One Set
(e) Aluminum sulfate

3. Piping:
Pipe of PVC 28 Bar tested pressure testing cock & pressure gauges at inlet-outlet of system
Sl. Parameter DESCRIPTIONS
(a) Make Astral
(b) MOC U-PVC
(c) Burst Pressure 28Kg/Bar
(d) Quantity 1 1 Lot

5. Micron Filter:
Purpose: To remove the fine particles up to 05 microns and reduce silt density Index levels to acceptable level.
Specifications:
Housing:
Sl. Parameter DESCRIPTIONS of Arsenic removal plant
(a) Make RAVE Filtration
(b) MOC of Housing PP
(c) Length 20”
(d) Diameter 5.5”
(e) Quantity One nos.
Cartridge
(f) Make Pure & Safe
(g) Cartridge MOC Polypropylene
(h) Length 20”
(i) Diameter 4”
(j) Quantity One nos.
(k) Micron Rating 05 Micron

No, it will not. The moment distilled water mixes with even a small amount of any food, it is no longer distilled. Pure water will contribute to cleanse your body of toxins. There is no scientific evidence that drinking distilled water will deplete you of any nutrients. The only theoretical case to avoid would be if you would go into a prolonged fast and drank only distilled water

Deionization is a good additional stage when the source water has over 250 ppm of TDS as in most California water supplies. This process utilizes a Deionization resin which captures the excess contamination that the Reverse Osmosis membrane and filters leave behind. This type of water can be obtained at quality commercial sources or it can be made at the point of use by an under the sink Reverse Osmosis DI. The purity of this water is equivalet to distilled water and it is most desirable for people that can have allergies (often undetected) to water borne contaminants even in small concentrations.

For most people who are conscious of their water needs and water quality, the safest water is one purified by Reverse Osmosis process, and the most cost effective solution is a point of use (POU) Reverse Osmosis system. Ranging between $200 and $500 depending on quality and performance, under the sink Reverse Osmosis systems provide a convenient and inexpensive way of obtaining pure water you can rely on. Many people prefer it because, regardless of cost, it is the ONLY way to guarantee that the water quality is up to the recommended standards.